C-TEC CFP Standard 2 Zone Conventional Fire Alarm Panel
Login to see price
Out of stock
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) and EN54 part 13 certified by Kiwa Telefication.
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Two detector zone circuits.
- Four conventional sounder circuits*
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test coincidence zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system) and optional CFP relay boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s ActiV fire detectors sounders and visual alarm devices.
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Black Friday Blowout!
Specification
Description
Certified to EN54 parts 2 4 and 13 C-TEC’s CFP 2 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price.
Supplied in an attractive flush or surface mountable plastic enclosure it includes two detector zones four conventional sounder circuits class change and alert inputs on-board fire and fault relays and combined keypad/keyswitch entry.
A wide range of engineering functions are also provided including selectable zone delays coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided.
Optional repeaters and relay expansion boards also available.
Approvals/certifications
Certifed to EN54 Parts 2 & 4 by the LPCB. Certified to EN54-13 by Kiwa Telefication.
Mains supply
230V 50/60Hz.
Mains rated current
350mA maximum.
Internal power supply
19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).
Total output current limited to
1.5A @ 230Vac (ImaxA eq 146mA).
Quiescent current
25mA (mains failed internal sounder active PSU & gen fault LED lit)
Max battery size and type
2 x 12V 3.2Ah VRLA connected in series. Min. battery size 1.2Ah.
No. of detector zone circuits
2 (Max. length per circuit is 500m).
Call point resistor value
470 to 680Ω.
Max. devices per detector zone
25 detectors (or 32 detectors/manual call points combined).
No. of conventional sounder circuits
4 (Max. length per circuit is 500m).
EOL resistor value
6800Ω 5% Tol. 0/25W (blue grey red gold).
Alarm voltage
27V max 20V min (final battery voltage)
Max. sounder output current
4 x 200mA (800mA total).
Auxiliary relays
Two: (1) Aux. Fire; (2) Fault. Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc.
Open collector outputs
Two: (1) Reset (Active during reset cycle); (2) Remote (Active during any unsilenced fire condition provided all relevant delays have expired). Max. sink current 30mA Max. open circuit voltag
Other outputs
24V Aux. Power (Protected by a resettable fuse. 100mA min. hold current. Resets when fault removed).
Auxiliary inputs
Two: (1) ‘Class Change’ (constant sounders); (2) Alert (pulsed sounders). Connect to 0V to trigger Max. input voltage 27V (non-latching)
Engineer (AL3) functions
Program coincidence (double knock); Invoke One Man Walk Test; Program delays; Set up zones for non-latching operation; Program sounders to resound (or not resound) when a new zone enters al
Expansion connections
Yes – for optional network driver cards (one required per repeater system) relay output cards and EN54-13 sounder circuit interface boards.
Product dimensions (mm)
380 W x 235 H x D 96mm (hole required for flush mounting = 367 W x 220 H x 75 D mm. No bezel required).
Construction & finish
Plastic lid and base; RAL7035 textured
IP Rating
IP30.
Weight
1.75kg (without batteries)
Operating conditions/temperature
-5ºC to +40ºC. Max relative humidity: 95%.